Southbend BELM-30 Fryer User Manual


 
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
www.yatesgd.com www.yatesgraphicdesign.com
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
OPTIONS and ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
ELECTRICITY: Power requirements are shown below. The skillet
must be grounded.
WATER: Optional faucets require 3/8" (10mm) outside-diameter tub-
ing connection to base of each faucet.
• Minimum clearance from combustible and noncombustible
construction is 3" (76mm) on sides and 6" (152mm) on rear.
Install on a noncombustible oor. Provide adequate clear-
ances for operation, cleaning, and servicing.
• Check local codes for re and sanitary regulations.
NOTICE:
Southbend has a policy of continuous product research and improve-
ment. We reserve the right to change specications and product
design without notice. Such revisions do not entitle the buyer to cor-
responding changes, improvements, additions or replacements for
previously purchased equipment.
Standard voltage options:
208 VAC, 1-phase, 50/60 Hz
208 VAC, 3-phase, 50/60 Hz
240 VAC, 1-phase, 50/60 Hz
240 VAC, 3-phase, 50/60 Hz
Additional-cost voltage options:
220 VAC, 3-phase, 50/60 Hz
380 VAC, 3-phase, 50/60 Hz
415 VAC, 3-phase, 50/60 Hz
480 VAC, 3-phase, 50/60 Hz
220/380 VAC, 1-phase, 50/60 Hz
240/415 VAC, 1-phase, 50/60 Hz
600 VAC, 3-phase, 60 Hz
18 kW power rating (BELM-40 only)
Pantry faucet(s) with swing spout(s)
Single (specify side)
Double
Enclosed support(s) for faucet(s)
Etched volume markings in pan
Gallons
Litres
Draw-off valve
2" (50mm)
3" (76mm)
Vented stainless-steel pan cover
Pan carrier (BELM-40 only)
Steam pan insert
Correctional package
Form BELM Rev 0 (05/07)
BELM-30 BELM-40
ledoMsesahP
eniLrepspmA
V802V022V042V083V514V084V006
03-MLEB
)Wk21(
17.755.450.05 ----
33.335.139.822.817.614.415.11
04-MLEB
)Wk51(
11.272.865.26 ----
36.144.931.638.229.020.814.41
04-MLEB
)Wk81(
15.688.180.57 ----
30.052.743.343.720.527.123.71
FRONT VIEW
C
D
B
REAR VIEWSIDE VIEW
TOP VIEW
23-1/2"
(597)
Pan Depth
9-1/8" (232)
28"
(711)
13-1/4"
(337)
40"
(1016)
33"
(838)
A
4" (102)
7-1/2" (191)
1-1/2" (38)
29-3/8" (746)
E
8-3/4" (222)
Water Connection
for Optional Faucet
Electric
Entrance
Four equally spaced 7/16” (11mm)
holes, 3” (76mm) between centers.
REAR FLANGED-FOOT DETAIL
sthgieWgnippihSdnasnoisnemiDcificepS-ledoM
ledoMABCDE thgieW
03-MLEB
"8/7-83
)789(
"2/1-33
)158(
"63
)419(
"8/5-33
)458(
"8/3-47
)9881(
sbl006
)gk272(
04-MLEB
"8/3-93
)0001(
"2/1-34
)5011(
"84
)9121(
"8/5-54
)9511(
"4/3-37
)9981(
sbl527
)gk823(
Dimensions shown in inches and (millimeters)