Southbend HDG-24 Griddle User Manual


 
HEAVY DUTY COUNTERLINE OPERATION
OWNERS MANUAL 1192662 PAGE 17
OPERATION
OPERATION OF OPEN-TOP BURNER MODELS
Each 12"-wide open-top burner section has two knobs on the front panel that directly control the flow of gas
to the section’s two burners, and so control the heat. Turn a knob clockwise to increase the heat; turn it
counterclockwise to reduce the heat.
If any burners do not light, check the pilots and, if necessary, light the pilots as described later in this
section.
At the end of each day’s use, turn all knobs to the “OFF” position.
To shut down the appliance for an extended period (or before disconnecting the gas supply), turn all the
burner control gas knobs “OFF,” then turn the main gas supply valve to “OFF.”
To light the pilots of an open-top burner section, do the following:
1. Turn all gas valves to the “OFF” position.
2. Check to make sure pilots are in the correct position.
3. Light the pilots. If the pilots will not remain lit, have a service technician adjust them.
4. Turn burner knobs to “HI” position. Each burner flame should be steady blue and impinge on the
underside of a pot placed on the support grate. If necessary, have a service technician adjust the
burners.
5. To turn burners off, turn knob to “OFF” position.