Southbend HDO-36SU Cooktop User Manual


 
HEAVY DUTY COUNTERLINE SPECIFICATIONS
SPECIFICATI
CLEARANCES
! WARNING
There must be adequate clearance between units and adjacent construction. Clearance must also be
provided for servicing and for operation. Measure back clearance from rear of 2" stand-off brackets.
Minimum Clearances from COMBUSTABLE construction:
Griddle Models Open Top Models
Sides 12" 10"
Back 8" 7"
Minimum Clearances from NON-COMBUSTABLE construction:
Griddle Models Charbroiler Model s Open Top Models
Sides 0" 0" 0"
Back 0" 0" 0"
ONS
VENTILATION
! WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove
flue products can cause h eadaches, drowsiness, nausea, or could result in death.
All units must be installed in such a manner that the flow of combustion and ventilation air are not
obstructed. Provisions for adequate air supply must be provided. Do not obstruct the front of the unit
at the top by the control panel as combustion air enters through these areas.
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be
covered by the warranty.
Air for combustion enters the rear of the appliance. An exhaust flue runs along the top rear edge of griddle
and charbroiler models.
Southbend recommends that a ventilation canopy extend 6" past the edges of the appliance and be located
6'6" above the floor.
If a wall exhaust fan is installed in the wall behind the appliance, it should be at least two feet above the top
of the appliance.
To avoid a negative pressure condition, return air must be brought into the room to replenish the air being
removed by the ventilation exhaust fan. RETURN-AIR FANS MUST NOT BLOW DOWN ONTO THE
APPLIANCE.
Ventilation filters should be installed at an angle of 45° or more from the horizontal. This prevents dripping
grease and facilitates collecting the run-off grease in a drip pan, usually installed with a filter.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s
instructions.
In case of unsatisfactory performance on any appliance, check the appliance with the ventilation exhaust
fan in the “OFF” position. Do this only long enough to check equipment performance. Then turn the fan
back on and let it run to remove any exhaust that may have accumulated during the test.
OPERATORS MANUAL 1182845 REV 6 PAGE 5