Southbend P16N-C Range User Manual


 
PLATINUM SERIES SECTIONAL RANGE SERVICE
INSTALL AND OPERATIONS MANUAL 1185836 REV 3 (07/06) PAGE 37 OF 80
Fi
g
ure 19
Adjustment of 33K and 45K Open-Top Burners and Pilots
The burner valves are not adjustable. The burner orifice is of the fixed type, sized for the type of gas and the operating altitude.
To adjust the burner air-gas mixture, loosen the screw that secures the air shutter on the mixer face and rotate the mixer cap
to obtain a clear, stable blue flame with a distinct inner cone at each port. Excessive primary air causes “blowing” (the flames
leaving the ports), while insufficient primary air causes a soft or yellow tipped flame.
The pilots are beside the burners, and are held in position by brackets. To adjust a pilot flame, insert a screwdriver through the
opening in the valve panel between the control knobs and turn the appropriate pilot adjustment screw counterclockwise to
increase the size of the pilot flame, or clockwise to decrease the size of the pilot flame. The maximum flame size is
approximately 3/4" with a slight yellow tip. The first indication of over-adjustment is when the flame tip becomes more yellow
and begins to generate carbon, which appears as rising black streaks. Continued over-adjustment leads to unstable lifting and
a blowing condition.
33K-Open-Burner Model
s
Adjustment screw for rear-burner pilot
Air Shutter
Access hole
for pilot
adjustment
Adjustment screw for front-burner pilot
Adjustment screw for rear-burner pilot
Air Shutter
Access hole
for pilot
adjustment
Adjustment screw for front-burner pilot