Southbend P36-RAD Convection Oven User Manual


 
INFRARED/RADIANT COMPACT BROILER INSTALLATION
INSTALLATION & OPERATIONS MANUAL 1186527 REV 3 (12/06) PAGE 15 OF 24
STEP 2B: MOUNT ON WALL
The Infrared/Radiant Compact Broiler is installed by first attaching a mounting bracket to the wall, then attaching the
broiler to the bracket.
1. Attach the wall-mount assembly to the wall using the six ¼” x 2” lag screws and six washers provided (see Figure
5). Screw through frame and into wall studs since the broiler weighs about 175 pounds (77 kilograms).
2. Check that the wall-mount is level (both side-to-side and front-to-back).
Figure 5
Installation of Wall Bracket for Infrared/Radiant Compact Broiler
3. It may be more convenient to prepare the gas supply line before the broiler is mounted on the wall bracket. If so,
install the supply line and connector now (but do not yet attach it to the broiler).
4. Lift the broiler (using two people is recommended) and hook the broiler-hook over the top of the front of the wall
bracket. If necessary, move the broiler left or right so that the holes in the top of the broiler hook line-up with the
holes in the wall bracket, then secure the broiler-hook to the wall-mount bracket using three sheet-metal screws.
5. Secure the bottom of the broiler to the wall-mount bracket with the four provided ¼” self tap screws. The holes are
accessible from the opening in the bottom of the wall-mount unit.
6. Go on to Step 3.