COUNTER GRIDDLE INSTALLATION
OPERATORS MANUAL 1182629 REV 2PAGE 15
INSTALLATION
Step 3: Attach Restraint for Griddles Mounted on Casters
NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that
complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors
for Moveable Gas Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the
Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect
Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate means must be provided to limit the
movement of the appliance without depending on the connector and the quick-disconnect device or
its associated piping to limit the appliance movement and (3) the restraining means should be
attached to a frame member on the back of the griddle.
Griddles mounted on a stand with casters or other movable surface must be equipped with a restraining
means to prevent accidental stress on the flexible gas connection.
1. Secure the restraining-device bracket (item “B” in the following illustration) to a wall stud located as close
as possible to the appliance connector inlet and outlet connections. Use four #12 screws (items “C”) and
plastic anchors (items “A”) if necessary.
2. Install eye-bolt (item “F”) to a frame member on the rear of the counter griddle. After checking carefully
behind the frame member for adequate clearance, drill a 1/4” hole through the frame member.
3. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through
the 1/4” drilled hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
4. Using the spring-loaded snap hooks, attach the restraining device to the bracket and the eye-bolt.
5. Using the cable clamp (item “D”), adjust the restraining device extended length to prevent over-bending
or kinking of the appliance connector.
Figure 10
Note: For griddles not equipped with flame safety devices, be sure all valves are turned off prior to
disconnecting. After reconnecting, be sure all valves are turned off and all pilots are lit.