Southbend STRE-5EZ Electric Steamer User Manual


 
SERVICE STRATOSTEAM COUNTERTOP STEAMER
PAGE 30 OF 44 OWNERS MANUAL 1185184
Figure 18
Water-Level-Control Sensor Check
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove the left and right side panels.
3. Remove bottom panel (four screws).
4. Remove insulation cover panel (four nuts).
5. Locate the water-level-control sensor (at the rear edge of the rear element block). Disconnect wires B1 and B2
from the sensor.
6. Place test leads across water-level-control sensor terminals (as shown above) and check for continuity when
the sensor is cool. If no continuity, replace sensor.
7. Reconnect wires and reassemble.