Stoelting 513588R1 Freezer User Manual


 
5
Figure 8 - Floor Stand
2.5 INSTALLING PERMANENT WIRING
If permanent wiring is required by local codes, the follow-
ing procedure must be performed.
WARNING
DISCONNECT FREEZER FROM THE SOURCE
OF ELECTRICAL SUPPLY BEFORE SERVICING.
A. Remove the right side panel.
B. Disconnect the wires from the terminal
block. Disconnect the green ground wire from the
grounding stud. (Fig. 9).
Figure 9. Power Cord Connection
C. Remove the power cord.
D. Install permanent wiring according to local code.
E. Replace the side panel.
2.4 FLOOR STAND INSTALLATION
To install the 0111 onto the floor stand, follow the steps
outlined below:
A. Uncrate the floor stand and place in an upright posi-
tion.
NOTE
Detailed instructions are included with each floor
stand.
B. Place a spirit level across the top of the stand to check
for level condition, side to side and front to back. If
adjustment is necessary, level the stand by turning
the bottom part of each caster in or out, then tighten
the lock nut.
C. Place supports under freezer, then remove the 4 legs
and replace with the rubber stud/plate mounts pro-
vided. Mounts must be fully tightened to the freezer.
D. Place the freezer base gasket on the floor stand with
the connected seam to the back and angle side up.
Center the gasket side to side and 1-3/4 inches from
the rear of the floor stand.
E. Place the freezer on the floor stand with the front of
the freezer to the door end. All 4 stud/plate mounts
must engage the holes in the floor stand. Secure the
mounts with the nuts and washers provided. (Fig. 8).