MODEL 427G / 427RG INSTALLATION
Anti-Tip Bracket
CONCRETE WEDGE ANCHOR INSTALLATION
1 Drill a
3
/8" (10) diameter hole any depth exceeding the
minimum embedment. Clean the hole or drill additional
depth to accommodate drill nes.
2 Assemble the washer and nut ush with the end of
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is ush with the
surface material.
3 Expand the anchor by tightening the nut 3–5 turns past
hand-tight position or to 25 ft-lb of torque.
WARNING
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
CAUTION
Always wear safety glasses and use other necessary
protective devices or apparel when installing or working
with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use in
new concrete which has not had sufcient time to cure.
The use of core drills is not recommended to drill holes
for the anchors.
Custom Panels
For models 427G and 427RG, custom panels and handle
hardware must be installed. Stainless steel panels are
available through an authorized Sub-Zero dealer. For local
dealer information, visit the nd a showroom section of our
website, subzero.com.
PANEL REQUIREMENTS
PANEL WEIGHT MAX
Door 20 lb (9 kg)
Drawer (427RG) 12 lb (5 kg)
PANEL THICKNESS MIN
All Panels
5
/8" (16)
Reveals between panels can vary,
1
/8" (3) reveals are typical.
CAUTION
When using a panel thicker than
3
/4" (19) with reveal less
than
1
/4" (6), panel may cause damage to the unit when
door is opened to 105°. Use the built-in 90° door stop.
CAUTION
As reveals between cabinetry and the unit decrease,
severe nger pinching can occur while door is closing.
Finish all sides of the custom panel. They may be visible
when the door is open or through the glass door.
D-style handles are recommended. Stainless steel tubular
and pro handles are avail able through an authorized
Sub-Zero dealer. For local dealer information, visit the nd
a showroom section of our website, subzero.com. The door
handle must be located near the edge of the panel opposite
the hinge and should be centered top to bottom.
CAUTION
A solid panel cannot be installed over the glass door. A
solid door is available through an authorized Sub-Zero
dealer. For local dealer information, visit the nd a
showroom section of our website, subzero.com.