Sub-Zero 430/O Beverage Dispenser User Manual


 
IMPORTANT NOTE:
If you are not responsible
f
or alarm system connection, this information
should be supplied to the home security
system contractor.
18
OTHER WIRING CONNECTIONS
Before the kickplate/grille is installed, all
n
ecessary wiring connections in the compres-
sor compartment should be completed.
I
f the dual installation heater kit (#7007529) is
used with Model 427 or 427R, the power
supply leads should be connected according to
i
nstructions included with the kit.
If a home alarm system is to be installed on
the Wine Storage unit, the connections should
be made using the logic supplied with the
alarm specifications. See illustration 8 below
for the appliance lead locations, and refer to
the following for color codes:
Normally open contacts – white with red
stripe wire
Normally closed contacts – white with blue
stripe wire
Common – gray with white stripe wire
Use the
1
/4" (6) spade terminals or wire nuts
provided to make the proper wiring connec-
tions.
MODELS 427 AND 427R INSTALLATION
The alarm circuit in the unit is intended as
a
low-voltage, low-current device only. It
should not be used to switch line power.
Any unused terminals should be
completely insulated and all wires should
be secured away from conductive or
moving components.
Home Alarm
Connections
Illus. 8
MODELS
427 | 427R
OPTIONAL
COMPONENTS
Optional installa-
tion components
are available
through your
Sub-Zero dealer,
or call Sub-Zero at
800-222-7820.
You can also visit
our website at
subzero.com.