Sub-Zero 700TFI Refrigerator User Manual


 
subzero.com/specs
|
7
INTEGRATED REFRIGERATION
Electrical
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit, servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
ELECTRICAL SUPPLY LOCATION
MODEL A
27" Model 13" (330)
36" Model 17
1
/2" (445)
Plumbing
The water supply line should be located within the shaded
area shown in the illustrations below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 20–100 psi
(1.4–6.9 bar) supplied
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply
1
/4" OD copper, braided
stainless steel or PEX tubing
Pressure 20–100 psi
(1.4–6.9 bar)
Excess Line for Connection 27" (686)
WATER SUPPLY LOCATION
MODEL A
27" Model 9" (229)
36" Model 13
1
/2" (343)
3" (76)
RIGHT SIDE
OF OPENING
A
3
/4" (19)
2
1
/2"
(64)
FLOOR
RIGHT SIDE
OF OPENING
A
2
1
/2"
(64)
1
1
/2" (38)
6"
(152)
BACK WALL
Water supply location (rear).
Water supply location (bottom).
A
1
/4" (6)
1
/4" (6)
4
1
/2"
(114)
2
1
/2"
(64)
FLOOR
LEFT SIDE
OF OPENING
Electrical supply location.