Sub-Zero BI-36UG Refrigerator User Manual


 
Dual Installations 30
Dual Standard Installations. Two framed, overlay
or stainless steel units may be placed side by side in a
dual installation. Some dual standard installations will
require a dual installation kit, available through your
Sub-Zero dealer. If you are installing two units side by
side in a flush inset application refer to page 33.
A custom filler strip can be used in between two units in a
framed, overlay or stainless steel design application. It is
recommended that the filler strip be at least 2" (51) wide,
to prevent condensation between the units. Be sure to
add the filler strip width to your rough opening width.
Refer to the full-scale template on page 41.
Dual installations without a filler strip can only be accom-
plished using two units with opposite hinges as shown in
illustration A below. The dual installations shown in illus-
trations B and C require a filler strip.
IMPORTANT NOTE: For the application shown in illustra-
tion A, a dual installation accessory kit is required. Refer
to page 36 for information on dual installation accessory
kits.
Dual Standard Installation
Dual Installation Panel Requirements
MAX WEIGHT PER PANEL
BI-36R, BI-36RG and BI-36F 75 lbs (34 kg)
All Other Models 50 lbs (23 kg)
Dual Wide Grille Panel 26 lbs (12 kg)
MIN PANEL THICKNESS
Framed Panels
1
/4" (6)
Overlay and Flush Inset Panels
5
/8" (16)
Illus. A
WITHOUT FILLER STRIP
FILLER STRIP REQUIRED
FILLER STRIP REQUIRED
Illus. B Illus. C
Dual Installations