Sub-Zero ICBBI-36F Refrigerator User Manual


 
6
BUILT-IN INSTALLATION SPECIFICATIONS
DOOR CLEARANCE
Side-by-Side Models
A
Model ICBBI-36S 527 mm
Model ICBBI-42S 649 mm
Model ICBBI-42SD 649 mm
Model ICBBI-48S 743 mm
Model ICBBI-48SD 743 mm
Door clearance is based on stainless
steel door and handle dimensions.
OVERALL DIMENSIONS
Side-by-Side Models
Model ICBBI-36S
WH D
914 mm 2138 mm 610 mm
Model ICBBI-42S
WH D
1067 mm 2138 mm 610 mm
Model ICBBI-42SD
with Dispenser
WH D
1067 mm 2138 mm 610 mm
Model ICBBI-48S
W
HD
1219 mm 2138 mm 610 mm
Model ICBBI-48SD
with Dispenser
W
HD
1219 mm 2138 mm 610 mm
Unit dimensions may vary by ± 3 mm.
9
14 mm
2134
mm
6
10 mm
1067 mm
1219 mm
1067 mm
2134
mm
610 mm
606 mm
BEHIND
FRAME
WIDTH
OF UNIT
A
1219 mm
2134
mm
610 mm
M
odel ICBBI-36S
Model ICBBI-42S Model ICBBI-42SD
Model ICBBI-48S Model ICBBI-48SD
Stainless steel design shown.
INSTALLATION SPECIFICATIONS
Side-by-Side Models—
Overlay (non-flush inset) and Stainless Steel
A
Model ICBBI-36S 902 mm
M
odel ICBBI-42S 1054 mm
M
odel ICBBI-42SD 1054 mm
Model ICBBI-48S 1207 mm
Model ICBBI-48SD 1207 mm
Dimensions are for finished rough openings.
INSTALLATION SPECIFICATIONS
Side-by-Side Models—
Flush Inset Application
AB
Model ICBBI-36S 902 mm 965 mm
Model ICBBI-42S 1054 mm 1118 mm
Model ICBBI-42SD 1054 mm 1118 mm
Model ICBBI-48S 1207 mm 270 mm
Model ICBBI-48SD 1207 mm 1270 mm
Dimensions are for finished rough openings.
1918 mm
178
mm
152
mm
E
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
457 mm
W
LOCATEWATER SUPPLY
WITHIN SHADED AREA
152
mm
FRONT VIEWSIDE VIEW
2127 mm
OPENING
HEIGHT
A
OPENING WIDTH
76 mm
610 mm
OPENING
DEPTH
1
3 mm
457 mm
*
152
m
m
610 mm
OPENING
DEPTH
SHUT-OFF
VALVE
OUTLINE OF
OVERLAY
OR STAINLESS
STEEL MODEL
TOPVIEW
*ANTI-TIP
BRACKET MUST NOT
INTERFERE
WITH WATER LINE.
REFER TO INSTALLATION
I
NSTRUCTIONS FOR COMPLETE
DETAILS.
EXTEND WATER LINE APPROX
914 mm FROM BACK WALL.
WATER LINE
1918 mm
178
mm
152
mm
E
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
13 mm
457 mm
*
152
mm
610 mm
OPENING
DEPTH
665 mm
FLUSH INSET
D
EPTH
SHUT-OFF
VALVE
OUTLINE
OF FLUSH INSET
APPLICATION WITH
19 mm PANEL
457 mm
W
LOCATEWATER SUPPLY
WITHIN SHADED AREA
152
mm
FRONT VIEWSIDE VIEW
TOPVIEW
2127 mm
OPENING
HEIGHT
2134
mm
FLUSH
INSET
HEIGHT
6 mm
56 mm**
76 mm
A
OPENING WIDTH
B
FLUSH INSET WIDTH
32
mm
32
mm
56
mm
**
610 mm
OPENING
DEPTH
665 mm
FLUSH INSET
DEPTH
*ANTI-TIP
BRACKET MUST NOT
I
NTERFERE
W
ITH WATER LINE.
REFER TO INSTALLATION
INSTRUCTIONS FOR COMPLETE
D
ETAILS.
**ASSUMES 19 mm PANEL
THICKNESS.
EXTEND WATER LINE APPROX
914 mm FROM BACK WALL.
WATER LINE
6
mm
32
mm
FLUSH INSET
DETAIL
56
mm
610 mm
OPENING
DEPTH