Sub-Zero ICBBI-36S Refrigerator User Manual


 
Built-In Refrigeration 23
subzero.com/specs
Dual Installation
FLUSH INSET APPLICATION
Installing two built-in models side by side in a flush inset
application will require adjustments to the dimensions of
your finished rough opening, panel sizes and panel offsets.
It will also require a dual installation kit, avail able through
your authorized Sub-Zero dealer.
Dual installations without a filler strip can only be accom-
plished using two units with opposite hinges as shown in
illustration A below. The dual installations shown in illus-
trations B and C require a filler strip. Refer to the full-scale
template on page 33. Illustration A is the only application
that will accommodate the dual wide grille.
IMPORTANT NOTE: The application shown in illustration A
can only be achieved by installing dual flush inset panels.
Failure to install dual flush inset panels will cause the
handle side of the panels to collide when closing. In this
application a dual installation accessory kit is also
required.
Dual flush inset panels and dual installation kits are avail-
able through your authorized Sub-Zero dealer. Refer to
pages 25–26 for dual flush inset panel specifications and
page 27 for information on dual installation kits.
Dual Installation Panel Requirements
MAX WEIGHT PER PANEL
All Models 23 kg
Dual Wide Grille Panel 12 kg
MIN PANEL THICKNESS
Flush Inset Panels 16 mm
Illus. A
WITHOUT FILLER STRIP
FILLER STRIP REQUIRED FILLER STRIP REQUIRED
Illus. B Illus. C