If ice production stops before the bin is full or continues
after the bin is full, ambient temperatures are probably too
high or too low. The level of ice can be adjusted by follow-
ing the steps below. The bin thermostat control is located
behind the kickplate. Refer to the illustration below.
1) To access the bin thermostat, remove the four screws
attaching the kickplate and tilt forward to remove.
2) Turn the bin thermostat control to the left to decrease
the level of ice or to the right to increase the level of ice
in the bin before automatic shut-off.
3) Reinstall the kickplate.
Ice Machine Operation 7
subzero.com
Operational Checks
The ice machine is factory tested and adjusted before
shipping. Normally, new installations do not require any
adjustment. Routine adjustments and maintenance proce-
dures are not covered by the warranty.
To ensure proper operation, follow the operational checks
when starting the ice machine for the first time, after a
prolonged out of service period and after cleaning and
sanitizing.
WATER LEVEL
The ice machine maintains the correct water level. The
water level is not adjustable.
BIN THERMOSTAT
The bin thermostat signals the ice machine to stop ice
production when the bin is full. It is preset for normal
ambient temperatures and adjustments are usually not
necessary.
To check operation of the bin thermostat, place three ice
cubes on the thermostat clip for about five minutes, ice
production should stop. The ice machine should restart
five minutes after the cubes are removed. Refer to the
illustration below.
Power is supplied to ice machine during this procedure.
Avoid contact with the fan blade and the electrical
connections.
THERMOSTAT
CLIP
Bin thermostat clip. Bin thermostat adjustment.
THERMOSTAT