Sub-Zero W362418(R) Ventilation Hood User Manual


 
Planning Information
Wolf Ventilation Recommendations
8
Dimensions in parentheses are in
millimeters unless otherwise specified.
PRO VENTILATION CFM RECOMMENDATIONS
Pro 24" (610) Deep Wall Hoods
W302418 W362418 W422418 W482418 W542418 W602418 W662418
DF304 / R304 / SRT304 600 600
DF366 / R366 / SRT366 / RT366 900 900
DF364 / R364 / SRT364 / RT364 900 900
RT362 900 900
R488 / RT488 1100 1100
DF486 / R486 / SRT486 / RT486 1100 1100
DF484 / R484 / SRT484 / RT484 1100 1100
R482 / RT482 1100 1100
DF606 / R606 1500 1500
DF604 / R604 1500 1500
NOTE: For optimal performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a
charbroiler or griddle.
Model numbers for dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops indicate width and number of surface
burners. Features such as a charbroiler, griddle and/or French Top will vary.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be
required for long duct runs.
PRO VENTILATION BLOWER OPTIONS
Pro 24" (610) Deep Wall Hoods
Blower Description Blower Number Wall Hood Models
600 CFM Internal WBLOWER-60INT (807614) W302418 / W362418 / W422418
900 CFM Internal* WBLOWER-90INT (805086) W302418 / W362418 / W422418
1200 CFM Internal WBLOWER-120INT (804702) W482418 / W542418 / W602418 / W662418
600 CFM In-Line* BLOWER-60IL (808331) W302418
1100 CFM In-Line* BLOWER-110IL (808332) All 24" (610) Deep Wall Hoods
600 CFM Remote BLOWER-60REM (801640) W302418
900 CFM Remote BLOWER-90REM (801641) W302418 / W362418 / W422418 / W482418 / W542418
1200 CFM Remote BLOWER-120REM (801642) All 24" (610) Deep Wall Hoods
1500 CFM Remote BLOWER-150REM (804701) All 24" (610) Deep Wall Hoods
*Vertical discharge with 10" (254) round duct. All other blowers are adjustable discharge with 10" (254) round duct. NOTE: For optimal
performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle.
Wall hood models without decorative rail listed; blower options are the same for (R) models. Transition with backdraft damper included
with all wall hoods. Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking
product. Always consult a qualified HVAC Engineer for specific applications.