Sub-Zero WS-30 Refrigerator User Manual


 
12
|
Sub-Zero Customer Care 800.222.7820
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp
Receptacle 3-prong grounding-type
CAUTION
The outlet must be checked by a qualied electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
13" (330)
1
/4"
(6)
4
1
/2"
(
114
)
LEFT SIDE
OF OPENING
FLOOR
2
1
/2"
(64)
Electrical supply location.
MODEL 427G / 427RG SITE PREPARATION
Preparation
Uncrate the unit and inspect for damage. Remove the wood
base and discard shipping bolts and brackets. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket and hardware.
IMPORTANT NOTE: For model 427RG, the upper drawer has
a control cable that must be disconnected before removing
the drawer. Refer to the illustration below.
Control cable (model 427RG).