Placing and Installation
Choosing the Right Place
Place the appliance in a dry and regularly ventilated room. Allowed ambient
temperature depends on the model (class) of the appliance and is stated on the
rating plate of the appliance.
Class Ambient Temperature
SN (sub-normal) from + 56°F to + 90°F
N (normal) from + 62°F to + 90°F
ST (sub-tropical) from + 64°F to +100°F
T (tropical) from + 64°F to +120°F
The appliance may be exposed to lower or higher temperatures but only for a
shorter period of time and the temperature should never be lower than 41°F.
Never place the appliance near heat emitting devices (e.g. cooker, radiator, water
heater or similar devices) and do not expose it to direct sunlight.
Placing the Self-Standing Appliance
It is important to make sure the appliance is leveled evenly to prevent falling.
Two spacers attached to the appliance must be fitted onto the upper edge of the
condenser, thus preventing the appliance from being installed too close to the
wall. Spacers are manufactured for all-purpose functions depending on the
distance of the condenser from the wall. Therefore turn spacers correspondingly
and adjust them accordingly to the appliance.
Connection to Power Supply
Connect the appliance with the cable and plug to the power supply socket outlet
with a ground terminal (safety socket).
“DO NOT USE AN EXTENSION CORD.”
Required nominal voltage and frequency are indicated on the rating plate.
The connection to the power supply and grounding has to be made according to
current standards and regulations. The appliance resists temporary voltage
tolerance up to -15 to 10%.