Teac 1824G&2424G Fryer User Manual


 
Dean
®
1824G & 2424G Flat-Bottom Gas Fryers
Model #_______________
CSI Section 11400
5489 Campus Drive
Shreveport, LA 71129
USA
Tel: 318-865-1711
Tel: 1-800-221-4583
Fax: 318-868-5987
E-mail: info@dean.enodis.com
http://dean.enodis.com
Bulletin No. 830-0046 9/08
Litho in U.S.A. ©Frymaster, LLC
MODEL
NO.
MIN./MAX.OIL
CAPACITY
OVERALL SIZE CM
DRAIN HEIGHT
DRAIN
VALVE
DRAIN VALVE
HEIGHT
FRYING
AREA
CU. FT.
WIDTH A DEPTH OVERALL
HEIGHT
WORK
HEIGHT
1824G 45-70 lb.
(22-35 liter)
20”
(51)
33”
(84)
45”
(114)
35”
(89)
1-1/4”
(3 cm)
15-1/4”
(39 cm)
18” x 24”
(46 x 61)
285/28
(129/0,8)
2424G 65-90 lb.
(32-45 liter)
26”
(66)
33”
(84)
45”
(114)
35”
(89)
1-1/4”
(3 cm)
15-1/4”
(39 cm)
24” x 24”
(61 x 61)
300/36
(136/1)
DIMENSIONS
POWER REQUIREMENTS
SHORT TERM SPECIFICATION
The following description will assist with ordering the features
desired for this equipment:
Shall be DEAN free-standing, flat-bottom deep fat fryer, Model____
____. Only _______” wide, _______# oil capacity, requiring 120,000
Btu/hr. (30,600 kcal) (35.2 kW) natural or LP gas input (3/4” N.P.T.
connection) (2 cm) and Thermatron solid-state temperature control
requiring 120V/2.0A.
ORDERING DATA
Please specify:
Natural or LP gas
Altitude -- if above 2000 ft.
DO NOT CURB MOUNT
FRONT VIEW
TOP VIEW
33.00
(84)
SIDE VIEW
(18)
7.20
35.00
(89)
(19)
7.62
(5)
2.00
(114)
45.00
(183)
6' POWER
CORD
(4)
1.50
w/ 3/4" NPT PIPE
CONNECTION
(4)
1.50
GAS LINE
A
INCHES
(cm)
We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
NATURAL OR LP GAS
INPUT RATING
GAS
CONNECTION
ELECTRICAL
REQUIREMENT
120,000 Btu/hr.
(30,600 kcal) (35.2 kW)
3/4” N.P.T. 120V/60~1Ø - 2.0A