Thermador CIT304DS Cooktop User Manual


 
Cabinet requirements The distance from the top of the cooktop to the bottom of cabinets above it must be
A = 30" (762 mm) min. This distance can be reduced to A = 24" (610 mm) when the
bottom of the wood or metal cabinet is protected by not less than 1/4" (6.35mm)
flame retardant millboard, covered by no. 28 MSG sheet steel, 0.015" (0.4 mm)
thick stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) thick copper.
Verify that cabinets above the cooktop are a maximum of B--13" (330mm) deep.
Cabinet Bottom
(Unprotected)
B
Building
Back
Wall WaEI
Surface
Electrical requiements You can find the identification plate with the electrical specifications on the
underside of the appliance. See "Product Data Plate" under "Service" for data plate
location. The junction box must be located within 3 feet of the cooktop connection.
It should be easily accessible for service purposes.
--&_
12" Approximate --
(Conduit approx. 3 feet)
Power Supply
Models CIT302DS, CIT304DS, CIT304EM
40 Amp circuit breaker
240 Volt, 3 Wire, 60 Hz
208 Volt, 3 Wire, 60 Hz
All with 1m flexible conduit (included)
6