Thermador HMWB36FS Ventilation Hood User Manual


 
187
1.800.735.4328 | THERMADOR.COM
VENTILATION — DOWNDRAFT
VENTILATION DOWNDRAFT (30"/36")
Models: UCVM30FS, UCVM36FS
INSTALLATION OPTIONS
The Thermador Downdraft Hood System is available in 30-inch
or 36-inch widths. It is intended for installation with Thermador
non-professional gas, electric or induction cooktops only.
A Recirculation Kit (RECIRC__FS) can be purchased separately and
used in conjunction with the Integral Blower if ducting to the outside
is not a viable option. Refer to the appropriate section for additional
specifications.
These hoods are designed to be used for vertical or horizontal discharge.
Dimension
depends
on Countertop
Dimension
depends
on Cabinet
Blower/Duct
Transition Box
Vent
ø6"
6"
10"
min.
1
/4"
1
/4"
9
1
/8"
5
1
/16"
21
5
/8"
6
5
/16"
14
3
/4"
3
1
/4"
2
1
/4"
2
1
/4"
CL
CL
CL
A
B
B
A
Point "P"
Center Line (CL)/
Plumbline
15
1
/2"
1
7
/8"
9
3
/4"
6
3
/8"
Cutout and
Overall
Dimensions
Cutout and
Overall
Dimensions
wide 31": 28
3
/8"
wide 37": 34
3
/8"
min.
1
/4"
SB
BT
1
/2"
2
1
/4"