Thermador HPWB30 Ventilation Hood User Manual


 
Fix Duct to transition and seal with tape.
For both installation method:
10.Wiring the HOOD:
WARNING:
Electrical Shock Hazard
Turnoffpower at the service
panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit
required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN
ELECTRICAL JUNCTION BOX WITH 3
WIRES, ONE OF WHICH (GREEN/YELLOW)
SERVES TO GROUND THE APPLIANCE.
TO PROTECT YOU AGAINST ELECTRIC SHOCK,
THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN
YOURHOME ELECTRICALSYSTEM,AND IT MUST
UNDER NO CIRCUNSTANCES BE CUT OR REMOVED
.
Failure to do so can result in death or
electrical shock.
Remove the j-box cover as shown in
Figure 5 .
If not already done, install 1/2” conduit
connector in j-box.
Run black, white, and green wires (#14
AWG) according to the National Electrical
Code or CSA Standards and local codes and
ordinances .
Connect black, white, and green wires from
power supply to black, white, and green/
yellow wires in j-box respectively.
Close j-box cover.
Final installation steps
1
1.Install grease lters, lamps and drip trays as
described in the Care & Use section of this
manual.
Note: Lamps are not supplied, use ONLY 120
Volt, 50 Watt (maximum) 50° halogen light
made for a GU10 base, suitable for use in
open luminarie.
Turn power on at service panel.
Figure 5
From
control
panel
10
To Avoid
WARNING: