Thermador PC36 Cooktop User Manual


 
CAUTION
(1) When connecting the unit to
propane gas, make certain
the propane gas tank is
equipped with its own high-
pressure regulator in addi-
tion to the pressure regula-
tor supplied with this unit.
The maximum gas pressure
to this appliance is not to
exceed 14.0 inches water
column from the propane
gas tank regulator.
(2) This unit is designed as a
cooking appliance. Based
on safety considerations,
never use it for warming or
heating a room.
This appliance has been tested
in accordance with ANSI Z21.1,
Standard for Household Cooking
Appliances (USA) and in accor-
dance with CAN 1.1-M81 Domes-
tic Gas Ranges (Canadian).
It is
strongly recommended that
this appliance be installed in con-
junction with a suitable overhead
vent hood. (See Step 1 for Ven-
tilation Requirements.) Due to
the high heat capability of this
unit, particular attention should
Important Installation Information
be paid to the hood and duct
work installation to assure it
meets local building codes.
Check local building codes for
the proper method of appliance
installation. Local codes vary.
Installation, electrical connec-
tions and grounding must com-
ply with all applicable codes. In
the absense of local codes the
appliance should be installed in
accordance with the National Fuel
Gas Code ANSI Z223.1 current
issue and National Gas Code
ANSI/NFPA 70 – current issue. In
Canada, installation must be in
accordance with the CAN 1-
B149.1 and .2 – Installation Codes
for Gas Burning Appliances and/
or local codes.
This appliance is equipped with
an intermittent/interrupted igni-
tion device that cycles the two far
left surface burners on and off
when in the ExtraLow
®
setting.
CAUTION
To eliminate risk of burns or
fire caused by reaching over
heated surface units, cabinet
storage located above the sur-
face units should be avoided.
2