Thermador PDR30 Range User Manual


 
Thermador
Professional Ranges Models: PDR30/36/48…PRG30/36/48
The control continuously monitors system parameters for control and oven failures and reports a fault code
when a system problem is detected. The control utilizes the ovens blue “on light” and oven “heating light” to
report a detected fault code. The control will continue to flash the lights in the appropriate sequence as long as
the fault exists.
Detection of a fault does not hinder the ability of the control to continue to function if the fault is not critical for
the intended operation. For example: If the range door latch is inoperative, the range will continue to cook since
the fault would only prevent the range from self-cleaning.
ERROR CODE LIGHT SEQUENCE CODE DESCRIPTION
E1 22 EEPROM ERROR
E2 01 CONTROL NOT CALIBRATED
E3 10 SENSOR OPEN
E4 12 SENSOR SHORTED
E5 21 POTENTIONMETER FAILURE
E6 32 OVER TEMPERATURE-COOKING
E7 23 OVER TEMPERATURE-CLEANING
E9 43 NO COOLING FANS
E11 44 DOOR LATCH FAULT
E12 11 EXP. BOARD NOT CONNECTED
E13 13 VCC LIFT OFF ERROR
E14 55 SELECTOR SWITCH ERROR