Thermador PRDS36 Range User Manual


 
STEP
6:
ELECTRICAL
REQUIREMENTS,
CONNECTION
&
GROUNDING
Recommended
Grounding
Method
-
All-Gas
Models
PRG304,
PRG36
and
PRG48
The
30,"
36"
and
48"
all-gas
ranges
are
factory
equipped
with
a
power
supply
cord with
a
three-prong
grounding
plug
(with
polarized
parallel
blades).
IT
MUST
BE
PLUGGED
INTO
A
MATING
GROUNDING
TYPE
RECEPTACLE
THAT
IS
CONNECTED
TO
A
CORRECTLY
POLARIZED
120
VOLT
CIRCUIT.
(See
Fig.
19).
Improper
grounding
will
cause
malfunc
tion
(such
as
continuous
sparking
of
the
burner
igniters),
may
damage
this
appliance,
and
could
create
a
condition
of
shock
hazard
at
the
igniter
of
each
burner.
If
the
circuit
does
not
have a
grounding
type
receptacle,
it
is
the
responsibility
and
obligation
of
the
installer
or
user
to
have
the
existing
receptacle
changed
to
a
properly
grounded
receptacle
in
accordance
with
all
applicable
local
codes
and
ordinances
by
a
qualified
electrician.
In
the
absence
of
local
codes
and
ordinances,
the
receptacle
replacement
shall
be
in
accordance
with
the
National
Electric
Code.
THE
THIRD
GROUND
PRONG
SHOULD
NOT,
UNDER
ANY
CIRCUMSTANCES,
BE
CUT
OR
REMOVED.
Alternate
Grounding
Method
-
All-Gas
Models
PRG304,
PRG36
and
PRG48
If
installing
a
properly
grounded
wall
receptacle
is
impossible
at
the
time
of
installation,
consult
your
local
electrical
inspector
for
permission
to
connect
a
temporary
adapter
(with
polarized
blades)
which
could
be
plugged
into
your
present
2-wire
receptacle.
(See
Fig.
20).
This
method
is
not
recommended.
If
this
is
done,
you
must
attach
the
lug
and/or
the
green adapter
wire
to
the
receptacle
cover
plate
screw.
Ground
from
it
to
a
grounded
metal
cold
water
pipe.
(See
Fig.
21).
DO
NOT
GROUND
TO
A
GAS
SUPPLY
PIPE.
Grounding
Method
-
Dual-Fuel
Models
PRDS304,
PRDS36
and
PRDS48
All
ranges
must
be
properly
grounded.
See
the
grounding
instructions
for
your
installation
case,
as
follows.
Refer
also
to
the
instructions
and
Figures
on
Pages
17
and
18.
CASE
1:
Electrical
Connection
and
Grounding
with
a
3
Conductor
Power
Supply
(To
be
used
when
local
codes
permit
grounding
through
the
neutral.)
Secure
the
neutral,
grounded
wire
of
the
supply
circuit
to
the
neutral
terminal
of
the
NEMA
10-50R
receptacle.
Connect
the
L!
(black)
and
the
L2
(red)
hot
heads
to
the
other
terminals
on
the
NEMA
10-50R
receptacle.
A
separate
ground
wire
is
not
required.
Ensure
that the
house
supply
wires
and
all
electrical
connections
meet
the
requirements
of
all
applicable
codes.
FIG.
19
Recommended
Grounding
Method
-
Models
PRG304,
PRS36
and
PRG48
THREE-PRONG
RECEPTACLE
THREE-PRONG
PLUG
FIG.
20
Alternate
Grounding
Method
-
Models
PRG304,
PRG36
and
PRSG48
FIG.
21
Grounding
Method
-
Models
PRDS304,
PROS36
and
PRDS48
METER
CLAMP
METAL
WATER
PIPE
Page
19