Thermador SGSX365FS Cooktop User Manual


 
113
1.800.735.4328 | THERMADOR.COM
MODEL OPTIONS
There are two sizes of Thermador Masterpiece
®
Gas Cooktops to choose from—30-inch and 36-inch.
30-inch models are available with four Star Burners
or five Star Burners. 36-inch models feature five Star
Burners. Every model is LP convertible by ordering
SNLPKITF. Be sure to reference the correct model
information in this design guide.
INSTALLATION CONSIDERATIONS
The information in this design guide provides key
features, product dimensions, cutouts and installation
specifications. Before installing a Thermador
Masterpiece Gas Cooktop, be sure to verify the cutout
dimensions and electrical/gas connections. Also,
always consult with the installation manual packed with
the product for complete details before installing.
Thermador Masterpiece Gas Cooktops may be
installed above a Thermador Single Built-in Oven as
long as there is no contact between the bottom of the
cooktop and the top of the oven.
Thermador Masterpiece Gas Cooktops may also
be installed above a Thermador Warming Drawer
to create a convenient cooking center. Refer to the
warming drawer section for additional specifications.
Solid surface countertops require a special cutout size
and special installation. For example, heat reflective
tape or rounded corners may be necessary. Contact
the countertop manufacturer for instructions specific to
your countertop.
VENTILATION REQUIREMENTS
We strongly recommend that a Thermador Ventilation
Hood be installed with all Thermador Masterpiece
Gas Cooktops. The hood must be installed according
to instructions furnished with the hood. Refer to the
ventilation section or www.Thermador.com for a
complete selection of ventilation options, blowers, and
accessories.
When installing the gas cooktop with a downdraft
ventilation system, provide approximately a 10
square inch opening (65cm
2
) in the toe kick area or
other cabinet area for adequate air inlet. Refer to the
downdraft ventilation section for more details.
WARRANTY
Limited warranty parts and labor (1 year)
See page 294 for additional warranty details.
ELECTRICAL AND GAS SPECIFICATIONS
Be sure your appliance is properly installed and grounded by a qualified
technician. Installation, electrical and gas connections, and grounding must
comply with all applicable local codes. Thermador Masterpiece Gas Cooktops
are equipped with a 60-inch, 3-wire supply cord.
Important: It is required that the cooktop be installed on a grounded,
non-GFCI branch circuit.
Thermador Masterpiece Gas Cooktops are shipped by the factory to operate
on natural gas. They must be converted for use with propane. Verify the type
of gas being used at the installation site matches the type of gas used by
the appliance. If the location/job site requires conversion from natural gas to
propane (LP), order SNLPKITF. Field conversion must be done by qualified
service personnel only. Please refer to the LP Conversion Instructions for
further information.
SUPPLY PRESSURE REQUIREMENTS:
Natural Gas - 7 inches water column (14.9 Millibars) minimum.
LP (Propane Gas) -11 inches water column (27.4 Millibars) minimum.
Note: The propane gas tank must be equipped with its own high pressure
regulator in addition to the pressure regulator supplied with this unit.
Plan the installation so that the power connection is accessible from the front
of the cabinet. Install a manual gas shutoff valve near the appliance. It must
be easily accessible in an emergency.
COOKTOPS — GAS
GAS COOKTOPS PLANNING INFORMATION
MODEL REQUIRED CIRCUIT BREAKER
120V, 60 Hz
SGS304FS 15 Amp
SGS305FS 15 Amp
SGSX305FS 15 Amp
SGS365FS 15 Amp
SGSX365FS 15 Amp
ELECTRICAL AND GAS LOCATIONS
The opening for the gas connection and electrical cord is located at the right
rear of rough-in box as shown below.
Opening for Gas
Connection and
Electrical Cord
for 30” models: 12 15/16” (313 mm)
for 36” models: 15 15/16” (389 mm)
C of Cutout
L
1”
I
G
S
N
E
D
C
D
E
E
R
I
T
I
F