Thermador VCIN54JP Cooktop User Manual


 
English 1
Introduction
Before using your appliance, be sure to read this manual.
Pay special attention to the Important Safety Instructions
beginning on page 2.
This manual provides information for two styles of
THERMADOR PROFESSIONAL
®
custom insert hoods:
VCINxxJP — 22” (559 mm) in depth, and with widths of
33¾” (857 mm), 45¾” (1,162 mm) or 51¾”
(1,315 mm). This model series features brushed
stainless-steel filters and halogen lights.
VCIBxxJP — 24” (610 mm) in depth, and with widths of
41½” (1,054 mm), 52½” (1,334 mm) or 58½” (1,486
mm). This model series features brushed stainless-
steel filters, halogen lights, hood liner, and a 1000CFM
integral blower.
All VCINxxJP hoods require the choice of a remote, inline,
or integral blower. Use only THERMADOR
®
blowers with
THERMADOR ventilation hoods. See Table 1, Blower &
Circuit Breaker Ratings for recommended blowers. Contact
Customer Service for additional options.
All hood models are rated for 120 VAC, using a 15 amp
circuit breaker; see the Installation Manual for more details.
Figure 1: Custom Insert
BLOWER SKU CFM *
VOLTAGE
(AC)
BLOWER
CURRENT
(AMPS)
CIRCUIT
BREAKER
(AMPS)
REMOTE BLOWER 600 CFM VTR630D 600 120 4.2 15
REMOTE BLOWER 1000 CFM VTRI030D 1000 120 5.7 15
R
EMOTE BLOWER 1300 CFM VTR1330E 1300 120 8.5 15
INLINE BLOWER 600 CFM VTI610D 600 120 4.2 15
INLINE BLOWER 1000 CFM VTI1010D 1000 120 5.7 15
INTEGRAL BLOWER 600 CFM VTN630C 600 120 2.7 15
I
NTEGRAL BLOWER 1000 CFM VTN1030C 1000 120 5.4 15
* CFM= Cubic feet per minute
Table 1: Blower & Circuit Breaker Ratings