Toastmaster TECF1527 Food Warmer User Manual


 
Toastmaster
®
COUNTERTOP FOODWARMERS
P
AGE4
SECTION V
Fusing
This warmer draws 4.0 amps at 120 Volts. Be sure the circuit to which it will be connected is adequately
wired and fused to accept this added load.
SECTION VI
A. Preventive Maintenance
Observe well for lime build-up. Remove as necessary. Lime will affect the performance of your unit.
B. Purpose of each electrical component.
ON/OFF Switch - Turn on power to device. Signal light glows to show power is on.
Operating Thermostat - (Thermo Disc Type for 1529), (Infinite Switch for 1523 and 1527)
Cycles heating unit on and off to maintain an average temperature of 170 (filled with water
level mark in well.)
Heating Unit - Offers heat to bottom of well.
Hi-Temperature Thermostat - (bi-metal type) turns buzzer on when water boils. (1529 Models).
Audible Buzzer - Signals operator to fill well with water immediately.(1529 Models).
TROUBLE SHOOTING INFORMATION
DURING NORMAL OPERATION (WATER IN WELL)
Symptom
1. No Signal Light
No Heat
No Buzzer
2. No Signal Light
Heats
3. Signal Light Glows
No Heat
4. Signal Light Glows
Buzzer Sounds
Symptom
1. Signal Light Glows
No Buzzer
Possible Cause
No incoming power.
Switch Defective.
Wire off.
Switch light defective.
Wire off.
Heating unit defective.
Operating thermostat defective.
Hi-temperature thermostat defective.
Possible Cause
Buzzer defective.
Hi-Temperature thermostat defective.
ABNORMAL OPERATION (NO WATER IN WELL - EVAPORATED DRY)