4
CLEARANCE
Minimum wall clearances for the sides and back of the models contained in this manual shall be as
follows:
Combustible Non-Combustible
Wall Wall
Hotplates 9" 0"
PRESSURE REGULATOR
A convertible pressure regulator set at 6" water column for use on natural gas is furnished. (For LP
models the regulator is set for 10" water column pressure.) Attach the regulator to the supply pipe,
located at the back of the unit, make sure gas ow arrow on regulator is pointing towards manifold.
The gas supply is then connected to the regulator. A 1/8" tap is furnished on the manifold for checking
pressure. The manifold is accessible by removing the front panel.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the unit and within six feet of the appliance,
and is not provided.
CONNECTING GAS SUPPLY LINE
The gas inlet on this appliance is sealed at the factory to prevent entry of dirt. Do not remove this seal
until the actual connection is made to the gas supply line.
CHECKING FOR GAS LEAKS
Soap and water solution or other material acceptable for the purpose, shall be used in locating gas
leakage. Matches, candle ame or other sources of ignition shall not be used for this purpose.
AIR SUPPLY
Provisions for adequate air supply must be furnished.
AIR INTAKES IN BOTTOM
Make certain the air intake openings in the bottom of the appliance are not obstructed. They are
essential for proper combustion and operation of the appliance.
EXHAUST CANOPY
It is essential that facilities be provided to carry off fumes and gases.
GAS INPUT OF OPEN TOP RANGES
For Natural Gas: Regulator output pressure set at 6" water column.
For Propane Gas: Regulator output pressure set at 10" water column.
Note: The appliance is equipped with natural gas orice hoods. A separate set of hoods will be
provided for use on propane gas. The propane hoods are located on the front panel.
Factory set LP models do not include the natural gas hoods.