SPECIFICATIONS
GENERAL INSTALLATION DATA
PLACE THE LAMINATED WARNING SIGN SUPPLIED WITH THE FRYER IN AN AREA
VISIBLE TO THE FRYER OPERATOR.
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for use
directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions & labels associated
with the unit prior to putting it into operation. Make sure all people associated with its use
understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This
unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If
equipment is received in damaged condition, either apparent or concealed, a claim must be made
with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked,
a request for inspection of concealed damage must be made with carrier within 15 days. Be
certain to retain all contents plus external and internal packaging materials for inspection. The
carrier will make an inspection and will supply necessary claim forms.
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE
"ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND
REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/
CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE
INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
WARNING: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing the equipment.
This appliance and control valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 PSIG (1.034 ATM). This
appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 PSIG (1.034 ATM). For your protection, we recommend a qualied installing
agency install this appliance. They should be familiar with gas installations and your local gas
requirements. In any case, your gas company should be called to approve the nal installation.
In addition, there should be posted, in a prominent location, detailed instructions to be followed in
the event the operator smells gas. Obtain the instructions from the local gas supplier.
FRYER SHOULD BE RESTRAINED TO PREVENT TIPPING WHEN INSTALLED TO
AVOID SPLASHING OF HOT LIQUID. USE ADEQUATE TIES WHEN INSTALLING
THE FRYER.
CAUTION
CAUTION
Model Height x Width x Depth Gas Connection NAT / LP
Weight
Installed Shipped
TMFG18
25.625” x 12” x 25” 3/8” NPT
24,000 BTU/HR
64 lbs 73 lbs
62.6cm x 30.5cm x 61cm 1cm NPT 29 kg 33.1 kg
TMFG30
23.375” x 24” x 25.125” 1/2” NPT Female NAT:70,000 BTU/HR 110 lbs 118 lbs
59cm x 61cm x 64cm 2cm NPT Female LP:65,000 BTU/HR 50 kg 54 kg