6
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED.
THIS DRAWING CONTAINS CONFIDENTIAL INFORMATION
#10 SUNNEN DRIVE
ST. LOUIS, MO. 63143, USA
FRACTIONS ± 1/64 DECIMALS ± .005 ANGLES ± 1°
TOLERANCES UNLESS OTHERWISE NOTED
DR. CK.
DATE
FINISH
MATERIAL
DESCRIPTION OF CHANGE
PART NO.
REVISIONS
MODEL NO.
TITLE
DATELTR DR
FRONT CONTROL
BACK CONTROL
FRONT ELEMENT
BACK ELEMENT
LIGHT
PILOT
PILOT
LIGHT
LEFT
RIGHT
X
Y
4
3
6
5
1
2
1
2
H
1
H
2
L
2
L
1
P
H
2
P
1
1
H
L
2
L
TMHPE/TMHPF
SK1986-1
WIRING DIAGRAM
09/01/2009
RDL
#10
AWG
17.5
240 V (1 PH)
NOMINAL AMPS PER LINE
USE GA. SHOWN (OR LARGER)
FOR SUPPLY CONNECTI0NS
3150 (208V)
4200 (240V)
RATED WATTAGERATED WATTAGE
3900 (208V)
5200 (240V)
TMHPF
TMHPE
#10
AWG
21.66
240 V (1 PH)
NOMINAL AMPS PER LINE
18.77
208 V (1 PH)
#10
AWG
TMHPF
208 V (1 PH)
15.14
AWG
#12
TMHPE
NOTE: FOR SUPPLY CONNECTIONS
USE COPPER WIRE ONLY, SUITABLE
FOR AT LEAST 90 DEG. C (194 DEG. F)