Toastmaster TMRC36 Oven User Manual


 
5
2M-Z12963: Gas Radiant & Lava Rock Charbroilers TMRC & TMLC
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas sufcient to meet
the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be
checked to determine if it has adequate capacity. Joint compound shall be used sparingly and only on
the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases.
WARNING: Any loose foreign material, debris, or metal particles allowed to enter the gas lines
on this appliance will damage the valve and affect its operation. When installing this appliance,
all pipe and ttings must be free from all internal loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each charbroiler. It should be connected to the
inlet pipe at the rear of the unit. The gas supply is then connected to it. It is shipped set for 6" water
column manifold pressure for use with natural gas. Allow 6" clearance from back of unit to wall for
servicing and installation.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed upstream from the manifold and within six feet of the
charbroiler.
CONNECTING GAS SUPPLY LINE
The gas inlet of the charbroiler is sealed at the factory to prevent entry of dirt. Do not remove this seal
until the actual connection is made to the gas supply line.
PROPANE GAS
This charbroiler is equipped with xed orice hoods and is shipped from the factory for use with
natural gas. To convert to propane gas, install the burner orice hoods, included with the unit, as
follows:
1. Remove grill, radiants and burners.
2. Remove the burner orice hoods and install the orice hoods supplied.
3. Replace the burners, radiants, and grill.
4. Set manifold pressure to (10) inch water column. A 1/8" pipe plug on the burner manifold can
be removed for attaching a pressure gauge. Remove the slotted, or hex-threaded plug from the
pressure regulator. Invert the plug and re-install. The letters "LP" should now be visible on the
plug. The regulator is now set for 10" (25.4 cm) water column. Attach the conversion label, supplied
with the unit, close to the nameplate.
CHECKING FOR GAS LEAKS
Check entire piping system for leaks. Soap and water solution or other material acceptable for the
purpose shall be used in locating gas leakage.
Matches, candle ame or other sources of ignition shall not be used for this
purpose.
CAUTION