Project Quantity Item #
Model Specified: CSI Section 11400
TRAULSEN
4401 BLUE MOUND RD. FT. WORTH, TX 76106
PHONE 1 (800) 825-8220 FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
SECTION
4-4
Refrigeration System
A top mounted, self-contained, balanced refrigeration system using R-404A
refrigerant is conveniently located behind the one piece louver assembly. It features
an easy to clean front facing condenser, thermostatic expansion valve, air-cooled,
semi-hermetic compressor, large, high humidity evaporator coil located outside the
food zone and a top mounted non-electric condensate evaporator. A 9' cord and
plug is provided. Standard operating temperature is 0 to -5°F.
Controller
The easy to use water resistant microprocessor control system is supplied standard.
It includes a 3-Digit LED Display, and a Fahrenheit or Celsius Temperature Scale
Display Capability.
Interior
Standard interior arrangements include three (3) epoxy coated wire shelves per
section, mounted on shelf pins, installed at the factory. Shelves are full-width, and
do not have any large gaps between them requiring the use of "bridge" or "junior
shelves." Recommended load limit per shelf should not exceed 225 lbs.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self-
contained models only) are provided standard. An optional 2
nd
year extended parts
and labor warranty is also available.
Continued product development may necessitate specification changes without notice.
Part No. TR35849 (revised 6/08)
NOTE: Freight charges are FOB destination for dock to dock delivery
within the continental USA. Liftgate delivery charges are additional.
For inside delivery charges, please consult factory.
Specifications
DIMENSIONAL DATA
G31010, G31011, etc.
Net Capacity cu. ft. 69.1 (1958 cu l)
Length Overall in. 76
5
⁄16 (193.8 cm)
Depth - Over Body in. 32 (81.3 cm)
Depth - W/Door Open 90° in. 56
7
⁄8 (144.5 cm)
Depth - Overall in. 35 (88.8 cm)
Clear Door Width in. 21
1
⁄8 (53.6 cm)
Clear Half Door Height in. 27
1
⁄2 (69.9 cm)
Clear Full Door Height in. 57
5
⁄8 (146.3 cm)
Number of shelves 9
Shelf area sq. ft.
1
51.9 (4.82 sq m)
Height - Overall in. 83
1
⁄4 (211.5 cm)
ELECTRICAL DATA
Voltage 115/60/1
Feed Wires with Ground 3
Full Load Amperes 15.8
REFRIGERATION DATA
Refrigerant R-404A
BTU/HR - HP
2
5220 (
3
⁄4 HP)
CARTON DIMENSIONS Domestic Crated Only
Length - Crated in. 91 (231 cm)
Depth - Crated in. 43 (109.2 cm)
Height - Crated in. 83
1
⁄2 (212.1 cm)
Volume - Crated cu. ft. 189 (5354 cu l)
WEIGHT DATA
Net Weight - Uncrated lbs. 690 (313 kg)
Gross Weight - Crated lbs. 870 (395 kg)
Plan View
Section View - All Models
Elevation View
Equipped with one NEMA 5-20P Plug
Construction, Hardware and Insulation
Cabinet exterior front, louver assembly and doors are constructed of 20 gauge
stainless steel. Cabinet sides (including returns), interior and door liners are
constructed of anodized aluminum. The exterior cabinet top, back and bottom are
constructed of heavy gauge aluminized steel. A set of four (4) 6" high casters are
included.
Doors are equipped with a gasket protecting metal door pan, removable plug
cylinder locks and guaranteed for life cam-lift, gravity action, self-closing metal, glide
hinges with stay open feature at 120 degrees. Hinges include a concealed switch to
automatically activate the interior incandescent lighting. Guaranteed for life, work
flow door handles are mounted horizontally over recess in door which limits
protrusion from door face into aisleways.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Both the cabinet and door(s) are insulated with an average of 2" thick high density,
non-CFC, foamed in place polyurethane.
NOTES
NOTE: Figures in parentheses reflect metric equivalents.
1= Figure shown reflects the area of standard shelf compliment plus
the additional storage area available on the cabinet bottom.
2= Based on a 90 degree F ambient and -10 degree F evaporator.
For remote data please refer to spec sheet 13-2.
REQUIRED CLEARANCES
In order to assure optimum performance, the condensing unit MUST have an adequate supply of
air for cooling purposes. Therefore, the operating location must either have a minimum of 12”
clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit.
Clearance of at least 12” above is required in order to perform certain maintenance tasks.