Traulsen RLT232DUT-FHS Freezer User Manual


 
Project Quantity Item #
Model Specified: CSI Section 11400
TRAULSEN
4401 BLUE MOUND RD. FT. WORTH, TX 76106
PHONE 1 (800) 825-8220 FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
SECTION
1-11
DIMENSIONAL DATA R/ALT132DUT R/ALT232DUT
Net capacity cu. ft. 17.7 (501 cu l) 42.0 (1190 cu l)
Length - overall in. 24 (61.0 cm) 48 (121.9 cm)
Depth - overall in. 35 (88.8 cm) 35 (88.8 cm)
Depth - less handle in. 33
3
4
(84.4 cm) 33
3
4
(84.4 cm)
Depth - over body in. 32 (81.3 cm) 32 (81.3 cm)
Depth - door open 90° in. 54
3
4
(139.1 cm) 54
3
4
(139.1 cm)
Clear door width in. 18
5
8
(47.3 cm) 19
9
16
(49.7 cm)
Clear half-door height in. 27
1
2
(69.9 cm) 27
1
2
(69.9 cm)
Clear full-door height in. 57
5
8
(146.3 cm) 57
5
8
(146.3 cm)
Height - overall on 6" legs 83
1
4
(211.5 cm) 83
1
4
(211.5 cm)
RLT Net Wt. lbs. 360 (163 kg) 619 (280 kg)
ALT Net Wt. lbs. 320 (145 kg) 560 (254 kg)
No. Standard Shelves 3 6
Shelf area sq. ft.
1
14.2 (1.3 sq m) 31.6 (2.9 sq m)
ELECTRICAL DATA
Voltage 115/60/1 115/60/1
Feed wires with Ground 3 3
Full load amperes 11.5 14.9
REFRIGERATION DATA
Refrigerant R-404A R-404A
BTU/HR H.P.
2
1890 (
1
2
HP) 3070 (
3
4
HP)
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and any
additional warranties.
Continued product development may necessitate specification changes without notice.
Part No. TR35765 (revised 1/07)
Construction, Hardware and Insulation
Cabinet exterior front, one piece sides, louver assembly and doors are constructed
of 20 gauge stainless steel with #4 finish. Cabinet interior and door liners are
constructed of stainless steel (anodized aluminum in the A-Series). The exterior cabinet
top, back and bottom are constructed of heavy gauge aluminized steel. A set of four
(4) adjustable 6" high stainless steel legs are included.
Doors are equipped with a gasket protecting metal door pan, removable plug
cylinder locks and guaranteed for life cam-lift, gravity action, self-closing metal, glide
hinges with stay open feature at 120 degrees. Hinges include a concealed switch to
automatically activate the interior incandescent lighting. Guaranteed for life, work
flow door handles are mounted horizontally over recess in door which limits
protrusion from door face into aisleways. Doors have seamless, polished metal
corners.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Both the cabinet and door(s) are insulated with an average of 2" thick high density,
non-CFC, foamed in place polyurethane.
Refrigeration System
A top mounted, self-contained, balanced refrigeration system using R-404A
refrigerant is conveniently located behind the one piece louver assembly. It features
an easy to clean front facing condenser, thermostatic expansion valve, air-cooled
hermetic compressor and a plenum effect blower coil. Two section models include a
large, high humidity evaporator coil located outside the food zone and a top mounted
non-electric condensate evaporator. One section models include an interior mounted
ceiling coil and bottom mounted electric condensate evaporator. A 9' cord and
plug is provided. Standard operating temperature is 0 to -5°F.
Controller
The easy to use water resistant INTELA-TRAUL
®
microprocessor control system is
supplied standard. Unit is NAFEM Data Protocol communication (NDP) ready.
Optional hardware required to be NDP compliant. Third party software required for
network connection. It includes a 3-Digit LED Display, Fahrenheit or Celsius
Temperature Scale Display Capability, Defrost Lockouts, and an RS485 data port.
In addition it includes audio/visual alarms for: Hi/Lo Cabinet Temperature, Door Open,
Clean Condenser, Evaporator Coil and Discharge Line Sensor Failures, and Power
Supply Interruption.
Interior
Standard interior arrangements include three (3) chrome plated wire shelves per
section, mounted on shelf pins. Shelves are full-width, and do not have any large
gaps between them requiring the use of "bridge" or "junior shelves." Recommended
load limit per shelf should not exceed 225 lbs. Optional tray slides may be
purchased in combination with, or in lieu of these. Both standard and optional
interior arrangements are completely installed at the factory.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self-
contained models only) are provided standard. An optional 2
nd
year extended parts
and labor warranty is also available. In addition the INTELA-TRAUL
®
control is
warranted by a two year parts and labor warranty.
Specifications
NOTES
NOTE: Figures in parentheses reflect metric equivalents.
1= Area of standard shelf compliment only, does not include storage area of additional shelves or available
on cabinet bottom.
2= Based on a 90 degree F ambient and -20 degree F evaporator.
3= For approximate remote weights deduct 40 lbs. from respective net or gross weight.For other information
on remote models, please refer to spec sheet 12-2.
Plan - R/ALT132DUT
Elevation -
R/ALT132DUT
Section - R/ALT232DUT
Plan - R/ALT232DUT
Elevation -
R/ALT232DUT
NOTE: Full load amps and plug style may vary depending
on electrical options chosen and condensing unit employed.
Section - R/ALT132DUT
One Section Models Equipped
With One NEMA 5-15P Plug
Two Section Models Equipped
With One NEMA 5-20P Plug