-4-
III. INSTALLATION (continued)
III. k - BUILT-IN INSTALLATION:
Select a proper location for your unit away from ex-
treme heat or cold. Due to the unique air flow of the
unit, the Spacesaver can be built-in or used as a free-
standing unit. Allow enough clearance between the
unit and side wall so that the doors can be opened a
minimum of 90 degrees. The floor should be level,
firm and capable of supporting the weight of the fully
loaded unit.
Follow the typical installation instructions outlined in
Section “III. a” thru “III. j” as required.
All built-in units require a minimum of 1/2” clearance
around the cabinet for servicing (see figure 5). If top
clearance exceeds 1” the unit must be blocked per
the free-standing instructions of Figure 6.
NOTE: If a self-contained unit is to be installed com-
pletely recessed, the front louvers must NOT be
blocked or replaced with a solid panel. The front lou-
vers allow good air circulation in the compressor com-
partment.