Tricity Bendix CLASSIC/1 Cooktop User Manual


 
27
Grill
Natural Gas L.P. Gas
Heat Input 3.0kW (10236 Btu/h) 2.75kW (197.5g/h)
Injector marking 120 080
Main Oven
Heat input 2.4kW (8189 Btu/h)
2.4kW (172.4g/h)
Injector marking 108 078
Thermostat bypass marking 069 078
General
Ignition (H.T. Spark)
Spark gap 3-4mm
Gas category countries of destination
CAT. I
2H
GB
CAT. I
3+
GB
This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC, Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68/EEC.