RATING PLATE
This is situated on the lower front frame of the
appliance and can be seen upon opening the top cavity
door. Alternatively the rating plate may also be found
on the back or top of some models (Where applicable).
The appliance must be protected by a suitably rated
fuse or circuit breaker. The rating of the appliance is
given on the rating plate.
Do not remove the rating plate from the cooker as
this may invalidate the guarantee.
INSTALLATION
If your cooker has been damaged in transit, contact
your supplier immediately. DO NOT attempt to install
it.
Your cooker left the factory fully packaged to protect it
from damage. If it is delivered without packaging and
damage has occurred, the manufacturer cannot
accept responsibility. Contact your supplier for advice.
Once the packaging has been removed the cooker
should only be moved by hand. DO NOT use a sack
barrow or any other aid to lift the cooker as damage
may occur.
Connection to the electricity supply must be carried out
by a qualified electrician/competent person.
The electrical connection should be made using a
double pole isolating switch (cooker socket) with at
least 3mm contact separation. The cable must have
conductors of sufficiently high cross-sectional area to
prevent overheating and deterioration.
The cable should be routed away from potentially hot
areas marked by X in the diagram below.
To move the cooker, open the main oven door and
lift the cooker by holding inside the top of the
compartment.
This is a type Y appliance which means it is
free-standing and can be fitted with cabinets on one
or both sides. It may also be fitted in a corner setting.
Side walls which are above hob level should be
protected by heat resistant non-combustible material
and MUST NOT be nearer than 40mm to the hob
side.
A nominal air gap of 2mm all around the cooker is
required to enable the cooker to be moved into
position
Always ensure an air gap is maintained at hotplate
level. Tiles or other forms of deep wall covering
should not obscure this gap.
Overhanging surfaces or a cooker hood should be a
minimum of 685mm above the hob.
It is important to ensure that the appliance is level
after installation. Levelling feet are fitted to the
appliance to accommodate uneven floors.
Six square millimetres (6.00mm²) is the recommended
cross-section area.
INTRODUCTION
WARNING: THIS APPLIANCE MUST BE
EARTHED
Air gap
8