True Manufacturing Company TGU-2 Refrigerator User Manual


 
............ www.truemfg.com ............
True Food Service Equipment, Inc.
7
7
INSTALLATION / OPERATION INSTRUCTIONS
Step 6
A. The compressor is ready to operate. Plug in the
unit.
B. Temperature control set at No. 4 position gives
refrigerators an approximate temperature of
35°F (1.6˚C) and freezers an approximate
temperature of -10°F (-23.3˚C). Allow unit
to function several hours, completely cooling
cabinet before changing the control setting.
C. Excessive tampering with the control could lead
to service difficulties. Should it ever become
necessary to replace temperature control, be
sure it is ordered from your True dealer or
recommended service agent.
D. Good air flow in your True unit is critical. Be
careful to load product so that it neither presses
against the back wall, nor comes within four
inches of the evaporator housing. Refrigerated
air off the coil must circulate down the back
wall.
NOTE
If the unit is disconnected or shut off, wait five minutes before
starting again.
RECOMMENDATION
Before loading product we recommend you run your True
unit empty for two to three days. This allows you to be sure
electrical wiring and installation are correct and no shipping
damage has occurred. Remember, our factory warranty does not
cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for your
unit. If at any time during the life of your display case, a part
is needed, you may obtain this part by furnishing the model
number and serial number to the company from whom you
purchased the cabinet. Call Toll-Free: (800)-424-TRUE (Direct
to Parts Department). (800)-325-6152 (U.S.A. & Canada only)
or call: (636)-240-2400.
STARTUP
Serial Number
REMOTE UNITS (This section applies to remotes only!)
Remote cabinets must be ordered as remote.
We do not recommend converting from a
standard self contained to remote system.
All remote cabinets must be hard wired.
No castors available.
All remote cabinets come standard using 404A
refrigerant.
All remote units come standard with expansion
valve, liquid line solenoid, heated condensate
pan, and defrost timer when applicable.
• Contact True Technical Service for BTU
requirements.
No wiring necessary between cabinet and
condensing unit.
All remote condensing units purchased from
True are 208/230 volts single phase.
If you have any questions regarding this section,