Turbo Air TGM-22RV Refrigerator User Manual


 
101
ELECTRONIC CONTROLLER INSTRUCTION
5-2. FUNCTION TABLE
No Control Function Control Objects Contents Remark
1 Initial Buzzer
Operation Fan
Lamp
88 LED
2 Temperature Compressor
Control
Evap-Fan Motor
Con-Fan Motor
LED
3 Turbo Compressor
Freeze
Evap-Fan Motor
Con-Fan Motor
LED
1. Buzzer will be ring within 2 seconds when you plugged-in and turned
on the power switch.
2. 88 LED displays inside temperature.
3. Compressor will be run if evaporator's temperature is higher than
38.3˚F(3.5˚C), compressor will not run for 3 minutes when you
plugged-in.
4. The fluorescent lamp will come on, when the inside temperature has
reached 23˚F(-5˚C).
5. If inside temperature is lower than -50˚F or higher than 50, 88 LED
displays 'Lo' or 'Hi' respectively.
6. Evap. Fan Motor will be run if D-sensor sense lower than 14˚F or 10
minutes has passed from when you plugged-in.
1. By pushing up/down button, you can set the desired inside
temperature from '5˚F' to '-17˚F'.
2. 88 LED will display a setting temperature, when you push up/down
button.
3. 88 LED will indicate real inside temperature, after your setting.
4. Buzzer rings 1 time whenever each button is pressed.
5. Compressor automatically turns on and off by F-sensor (Except
error mode)
6. Compressor will not come on for 3 minutes After Compressor is Off,
even though the F-sensor is at On point.
7. Evap. Fan Motor runs continuously except when door is opened and
during defrost mode.
8. Evap. Fan Motor will start within 3 seconds when door is closed.
9. Compressor On/off temperature(˚F)
1. If the Turbo Freeze button is pressed, the Turbo freeze mode will
start.
2. If the Turbo Freeze button is pressed during the Turbo Freeze mode,
the Turbo Freeze mode is cancelled.
3. During the Turbo Freeze mode, the temperature up/down button will
not by operated.
4. T.F lamp in 88 LED is lighted during the Turbo Freeze mode.
5. The compressor and Condenser-Fan Motor operate continuously for
120 minutes.
Setting
Comp On
Comp Off
Setting
Comp On
Comp Off
Setting
Comp On
Comp Off
Setting
Comp On
Comp Off
Setting
Comp On
Comp Off
5
9
1
0
4
-4
-5
-1
-9
-10
-6
-14
-15
-11
-19
4
8
0
-1
3
-5
-6
-2
-10
-11
-7
-15
-16
-12
-20
3
7
-1
-2
2
-6
-7
-3
-11
-12
-8
-16
-17
-13
-21
2
6
-2
-3
1
-7
-8
-4
-12
-13
-9
-17
1
5
-3
-4
0
-8
-9
-5
-13
-14
-10
-18