www.U-LineService.com 4 09/2008
1075WC
PRODUCT DIMENSIONS
Please note that the unit has adjustable feet that can add
one additional inch to height during leveling or to match
adjacent cabinets (see Figure 9).
DOOR SWING/CLEARANCES INFORMATION
All 1075 units have a zero clearance for the door to open
90° (see Figure 3). Stainless units require a minimum of
2" door clearance to accommodate the handle if the unit
is installed next to a wall or similar type of structure.
OTHER SITE REQUIREMENTS
Power Supply
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications on Page 7.
Environmental Requirements
Many U-Line models are designed to operate in harsh
outdoor/marine environments. Special considerations
include the following:
• The units are designed to operate between 50°F (10°C)
and 110°F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit’s ability to reach
low temperatures.
• For best performance, keep the unit out of direct
sunlight and away from heat generating equipment.
• In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.
• U-Line does not recommend installation of glass front
models (Wine Captain
®
wine storage models and
Beverage Centers) as well as the Combo Drawer model
(Refrigerator/Freezer/Ice Maker) outdoors, or in
tropical climates where high humidity and dew point
are present on a regular basis, unless air-conditioning
(typical 72°F, 75%RH) will be used.
SIDE-BY-SIDE INSTALLATION INSTRUCTIONS
For a complete refreshment center, install two of the
following 1175/1075 series units side by side: 1175R,
1175WC or a 1075 BEV Center. Note that each Side-By-
Side Installation will be different.
• Cut-out width for a side-by-side installation is the total
of the widths listed under Cut-Out Dimensions in each
unit’s Installation Guide.
For example:
Placing a 1175R next to an 1075 series unit would
require a cut-out width of:
24-3/16" + 24-3/16" = 48-3/8"
•
No trim kit is required. However, 1/4-inch space needs to
be maintained
between the units to ensure
unobstructed door swing.
• Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s
Electrical Specifications.
34-1/8"
23-15/16"
25-7/16"
Including
Handle
ULIN
_
1060
_
A
Figure 2
Wall
2" Min.
90°
Door Swing
20-7/8"
25-1/4"
Wine Captain 1075WC