3-42
Section 3 - Service and Repair
CAUTION
If frost is heavy, divert water from drain to prevent water
from overflowing on the floor.
SPECIFICATIONS
CLR2160
COMPRESSOR/COIL SPECIFICATIONS
DANGERDANGER
Electrocution can cause death or serious injury. Burns from
hot or cold surfaces can cause serious injury. Take precautions
when servicing this unit.
• Disconnect the power source.
• Do not stand in standing water when working around
electrical appliances.
• Make sure the surfaces you touch are not hot or
frozen.
• Do not touch a bare circuit board unless you are
wearing an anti-static wriststrap that is grounded to
an electrical ground or grounded water pipe.
• Handle circuit boards carefully and avoid touching
components.
To measure the start winding resistance measure across the C and
S pins.
To measure the run winding resistance measure across the C and R
pins.
Also check S to R and you should get the sum of the run and start
windings.
To ensure the windings are not shorted check the S and R to
ground.
Figure 26. CLR2160
Water Valve 275 Ohms
Bypass Coil 300 Ohms
Pump Motor 72 Ohms
THERMISTORS
The U-Line Model CLR2160 uses two thermistors. The
thermistors are used in conjunction with the control panel to
monitor the unit’s functions and troubleshooting capabilities. A
type 1 thermistor is attached to the condenser dryer inlet and
senses temperature after the condenser to signal length of ice-
making and harvesting time. A type 2 thermistor senses the ice
level in the ice bin and maintains ice level in the bin.
REED SWITCH
None on this model.
EMY70HER
Voltage 115-127
Frequency 60.0
LRA 26.5
FLA 2.7
Start Winding 8.1
Run Winding 3.2
Capacitor N/A
C
S
R
ULIN_0568_A
STARTING
RELAY
3/4" OVERLOAD
PROTECTION