4 Product Operation Touch Control
Air Flow
IMPORTANTIMPORTANT
The unit requires proper air flow to perform at its highest
efficiency. Do not block the front grille or internal fans at
any time, or the unit will not perform as expected. Do not
install the unit behind a door.
To turn the unit on or off, press and hold the POWER icon (1) for
about ten seconds and release. The display will show the unit set-
point temperature when turned on and display OFF when the unit
is off.
Electronic Control Panel
Digital Display.
The electronic control with digital display shows a single
continuous set-point temperature. This set point is for the middle
zone, it is a base number used by the controller to maintain the
multiple temperature zones in the unit. The factory default set-
point for Beverage Center and Refrigerator models is 38°F. The
factory default set-point Wine Captain models is 50°F. The set-
point temperature is a gauge for further temperature adjustments.
Adjusting Air Temperature
IMPORTANTIMPORTANT
Adjust the set point temperature in single increments,
and wait 24 hours for the temperature to stabilize before
rechecking.
To adjust the set point temperature:
1. Press and release either the WARMER (2) or COOLER (4)
icon to put the controller in the SET TEMPERATURE mode.
The display (3) will begin to flash the °F (or °C) symbol.
NOTE: This mode will self-cancel in five seconds, and the
display (3) will show the original set-point temperature.
2. Within five seconds (while the °F (or °C) symbol is flashing),
press the WARMER or COOLER icon as required to adjust the
set point temperature.
3. The change sets five seconds after adjusting the temperature,
and the display (3) will show the new set-point temperature.
Temperature °F °C Selection. U-Line products supplied for
110 VAC have temperatures displayed (3) default in Fahrenheit
(°F). Models supplied for 220 VAC have temperatures displayed (3)
default in Celsius (°C).
Easily adjust the display for either type of temperature display.
Press and hold the LIGHT icon (1) and simultaneously within
five seconds press the COOLER icon (5) three times to change
the display (3) as needed.
Temperature Display. The digital display shows set-point. air
temperature. Under normal operating conditions the
temperatures will fluctuate based on a number of factors including
door openings, product load, room temperature, and humidity. On
passive cooled units the temperature will always be cool toward
the top and coolest toward the bottom.
To display actual temperature:
1. Press the WARMER icon (2) for five seconds. The display (3)
will indicate the actual temperature.
2. After about 10 seconds, the set point temperature will return to
the display.
Initial Startup
All U-Line controls are preset at the factory. Initial startup requires
no adjustments.
IMPORTANTIMPORTANT
U-Line recommends allowing the unit to run overnight
before loading refrigerator or freezer with product.