U-Line CLR1215 Refrigerator User Manual


 
QUICK START GUIDE
10
u-line.com
The ice cube thickness is factory set for best overall
performance. The factory setting “0” is designed to
maintain an ice bridge of approximately 1/16" to 1/8"
(1.6 mm to 3.2 mm) under normal conditions, resulting in
a dimple of approximately 1/4" to 1/2" (6.4 mm to
12.7 mm) in depth. A fuller cube with less of a dimple
results in a thicker ice bridge. As the ice bridge becomes
thicker, the tendency for the cubes to stay together as a
slab increases. A bridge thicker than 1/8" (3.2 mm) may
cause cubes to overfill the ice bucket.
Adjust ice thickness as follows:
1. Press and hold for 5 seconds (display will show
current settings).
2. Press to make cube thicker or
to make cube
thinner.
The total range of adjustment is -5 (thinest) to +5
(thickest). If further adjustments are desired, repeat
steps 1 and 2.
L
Sabbath Mode
U-Line Clear Ice Machine models are Star-K certified and
can be used during the Sabbath. View a full list of Star-K
certified U-Line units at www.star-k.org.
To prepare the unit for the Sabbath:
1. Press and hold until the unit turns off.
2. No new ice will form when the unit is off, but previously
made ice will still be accessible/present for over 24
hours. Pump equipped models will continue to remove
water as needed even if the unit is off.
Sabbath Mode remains active until is pressed again
and the unit turns on.
DIMPLES
ICE BRIDGE
Ice Bridge and Dimples
THIN BRIDGE THICK BRIDGE
DEEP DIMPLE
LITTLE OR
NO DIMPLE
1/4" TO 1/2"
(6.4 mm to 12.7 mm)
DIMPLE
1/16" TO 1/8"
(1.6 mm to 3.2 mm)
ICE BRIDGE
Cube Types
Power