U-Line CLR2160 STAINLESS Refrigerator User Manual


 
16 U-Line Combo® Models and Ice Makers Service
9Service
Problem Possible Cause and Remedy
Unit Does not
operate.
Electronic
display blank
No electrical supply. Plug unit in or check circuit
breaker
No Interior
light
CLRCO2175, Tighten or replace bulb, See
Maintnence) CLR2160, Contact Service.
Display showing
error code
If display shows error E3, door is not sealing
correclty. Make sure to close door compleatly. If
display shows any other errors, record the error and
call for service.
Unit Develops
Condensation
on External
surfaces
The unit is exposed to excessive humidity, moisture
will dissipate as humidity levels increase.
Product is
Freezing in
Combo Models.
Adjust the temperature to a warmer set-point. (See
OPERATION)
Product is Not
Cold Enough in
Combo models.
Air temperature does not indicate product
temperature. See OPERATION - Checking Product
Te mperat ur e .
Adjust the temperate to a cooler set-point. (See
OPERATION)
Ensure unit is not located in excessive ambient
temperatures or in direct sunlight.
Ensure the door is closing and sealing properly.
Ensure the interior light has not remained on too
long.
Ensure nothing is blocking the front grille, found at
the bottom of the unit.
Ensure the condenser coil is clean and free of any dirt
or lint build-up.
Poor Ice quality. Unit may notbe level. Check unit for levelness. (See
Maintnence) Ice maker system may be dirty. Clean the
ice maker. (See Maintnence)
No Ice
Production
Ensure water is being supplied to the unit. .Verify the
ice making unit is turned on (See operation)
Not Enough Ice Ensure the condenser coil is clean and free of any dirt
or lint build-up.
Water in Bucket Drain may be, ensure drain is free of foreign debris.
Normal Operating Sounds
All models incorporate rigid foam insulated cabinets to provide
high thermal efficiency and maximum sound reduction for its
internal working components. Despite this technology, your model
may make sounds that are unfamiliar.
Normal operating sounds may be more noticeable because of the
unit’s environment. Hard surfaces such as cabinets, wood, vinyl or
tiled floors and paneled walls have a tendency to reflect normal
appliance operating noises.
Listed below are common refrigeration components with brief
description of the normal operating sounds they make. NOTE:
Your product may not contain all the components listed.
Compressor: The compressor makes a hum or pulsing sound
that may be heard when it operates.
Evaporator: Refrigerant flowing through an evaporator may
sound like boiling liquid.
Condenser Fan: Air moving through a condenser may be heard.
Automatic Defrost Drain Pan: Water may be heard dripping or
running into the drain pan when the unit is in the defrost cycle.
Troubleshooting Guide
DANGER
ELECTROCUTION HAZARD. Never attempt to repair or
perform maintenance on the unit until disconnecting the
main electrical power.
Troubleshooting - What to check when problems occur:
Before Calling for Service
If you think your U-Line product is malfunctioning, read the
OPERATION section of this guide to understand clearly the
function of the control.
If the problem persists, read the NORMAL OPERATING
SOUNDS and TROUBLESHOOTING GUIDE section of this guide
to help you quickly identify common problems, and possible causes
and remedies. Most often, this will resolve the problem without
the need to call for service.
If Service is Required
If you do not understand a troubleshooting remedy, or your
product needs service, contact U-Line Corporation directly.
Contact information appears on the rear cover of this guide.
When you call, you will need your product Model and Serial
Numbers. This information can be recorded inside the front cover
of this guide. It also appears on the Model and Serial number plate
located on the upper right or rear wall of the interior of your
product.
Replacement Parts
When you need replacement parts, always request genuine U-Line
replacements. U-Line designs and engineers products using
components that work efficiently, and provide superior service life
and performance. The use of aftermarket parts or components
may affect the safety, operation, performance or durability of your
product, and may also void its warranty.