U-Line U-3060RDCOL-00 Freezer User Manual


 
6 u-line.com
3045/3060 Model
1. To begin, press U-Select Lighting to enter the lighting menu.
2. Use Up or Down to cycle through each available brightness
setting; Low, Medium, or High.
3. Use U-Select Lighting
to cycle through each available timer
setting. Selections include “On With Door”, “On 3 Hours”, “On 6
Hours”, or “On 24 Hours”.
4. To exit, press Select
or simply wait for the menu to time out.
Error Notification
The 3000 model series continuously monitors a series of inputs and
parameters to ensure proper and efficient operation of your unit.
Should the system detect a fault, an error notification will be displayed
on the user interface. See below for a list of errors
Note: Singe zone models will not use (L) left or (R) right zone
indicators in error notification.
Customer Menu
The 3000 Series of U-Line undercounter refrigeration appliances
contain a feature rich customer menu. The Customer Menu allows
access to a Series of advanced features including Energy Saver Mode,
Sabbath mode, actual temperature readings as well a method to
restore factory defaults.
3000 Series - Customer Menu
1. To access the Customer Menu hold Select for 5 seconds.
2. Use Up or Down to scroll through available selections.
3. Use Select to enter selected sub-menu.
4. To exit Customer menu, Use Down to scroll to the bottom of
the display and use Select to Select “Exit.”
Actual Temps
The Actual Temps option displays the actual temperature of each zone,
evaporator, as well as climate range.
1. To view actual temperature, Select Actual Temps from the
customer menu.
2. Use Up or Down to scroll through available information.
3. To return to the customer menu, Select
Return to Menu.
Energy Saver Mode
Energy Saver mode reduces overall energy consumption by altering
user set point, differential, lighting and tone settings. When in Energy
Saver mode a small leaf icon will be displayed on the main screen.
1. To enter Energy Saver first select Energy Saver from the
Customer Menu.
2. Use Down to select “Off” in the menu.
ID Description Solution
No Comm Unit lost
communication to the
display.
Disconnect and reconnect
power to unit. Contact
customer care if
persistent.
(L) (R) Zone T
Open
Left or right zone
thermistor circuit
open.
Contact Customer Care.
Amb Thrm Open Ambient thermistor
circuit open.
Contact Customer Care.
(L) (R) Zone T
Short
Left or right zone
thermistor circuit
shorted.
Contact Customer Care.
Amb Thrm Short Ambient thermistor
circuit shorted.
Contact Customer Care.
(L) (R) Temp Hi
6H+
Left or right Zone
temperature +10°
over set point for over
6 hours.
Verify door is closed and
sealing. Contact customer
care if persistent.
(L) (R) Temp Hi
12H+
Zone temperature
+10° over set point for
over 12 hours.
Verify door is closed and
sealing. Contact customer
care if persistent.
(L) (R) Temp Lo
6H+
Zone temperature
-10° under set point
for over 6 hours.
Verify door is closed and
sealing. Contact customer
care if persistent.
(L) (R) Temp Lo
12H+
Zone temperature
-10° under set point
for over 12 hours.
Verify door is closed and
sealing. Contact customer
care if persistent.
(L) (R) Door
Open 5M
Door switch open for
more then 5 minutes.
Verify door is closed and
sealing. Contact customer
care if persistent.
Up
Select
Down
U-Select Lighting
Power
Up
Select
Down
WELCOME TO THE
CUSTOMER MENU. USE
UP/DOWN ARROWS TO
SCROLL SETTINGS.
Up
Select
Down
RETURN TO MENU
ACTUAL TEMPS
BIN TEMP = 2°C
COND TEMP = 46°C
Up
Select
Down
Energy Saver Mode
Indicator
ICE PRODUCTION
(12m remaining)