U-Line U-CLRCO2175S-41 Ice Maker User Manual


 
u-line.com 5
Electronic Control Quick Guide
Ta s k Touch Touch Display Comment
Turn ON/OFF Hold 5 seconds Release when °F flashes. or
Adjust
Te mperat ur e
CLRCO2175
or
Touch and release
or
Touch to change temperature
°F flashes after first touch,
set-point saved after 5
seconds of inactivity and °F
stops flashing.
View Actual
Te mp
CLRCO2175
Hold 5 seconds Release when °F flashes.
WC models will scroll top/
mid/bottom temps.
Change F/C
CLRCO2175
Hold or
Blackout Mode Hold 10 seconds
Display (and cabinet light) will not
operate in Blackout Mode.
Blackout will end in 36
hours, or hold again to
terminate early.
Clear Ice & Clear ice Combo
Clean Cycle
Will automatically return to
ice production when clean
cycle is complete
Ice Thickness
Adjustment
Use warmer/colder to
scroll.
Te mporary
Shutdown
(Office Mode)
Ice maker will automatically
turn back on in three hours.
Combo Ice
Maker Off
Repeat to switch back
NOTE: 38°F is an example; the display will vary with actual set-point.