Verona VECTGMS365SS Cooktop User Manual


 
ENGLISH
Use & Care Manual
6
Models and Part Identification
1. 1,300 to 6,300 Btu/h burner &
control knob
2. 1,700 to 15,000 Btu/h burner &
control knob
3. 1,300 to 9,000 Btu/h burner &
control knob
4. 1,700 to 12,000 Btu/h burner &
control knob
5. Burners cap
6. Burners gas spreader
7. Grates
8. Model and serial number
(under cooktop box)
1. 00 to 00 Btu/h burner & control knob
2. 000 to 000 Btu/h burner & control knob
3. Double crowns
–  to  Btu/h burner & control
knob
4.  to 100 Btu/h burner & control knob
5.  to 100 Btu/h burner & control knob
6. Burner caps
7. Gas spreader
8. Grate
9. Model and serial number (under cooktop box)
Appliance installed over 2,000 feet (610mt)
De-rate effect
Cook top
Nominal values
Btu/h from
0 to 2,000 (610)
Elevation
from 2,000 (610)
to 4,000 (1220)
Elevation
from 4,000 (1220)
to 6,000 (1829)
Elevation
from 6,000 (1829)
to 8,000 (2438)
Elevation
from 8,000 (2438)
to 10,000 (3048)
30”
4 burners
42,300 38,916 35,802 32,937 30,302
36”
5 burners
55,000 50,600 46,552 42,827 39,400
(De-rated 4% per 1000 feet)