Verona VEFSEE 244 P.. Range User Manual


 
11
4-Wire Conduit Installation
(See Figures 2.1, 2.7, 2.8 and 2.10)
1. Remove the Terminal Block Access Plate on the back of the
range by unscrewing the 4 fixing Screws (fig. 2.1).
2. Remove the Bracket and Strain Relief group by unscrewing
the Bracket Fixing Screws (fig. 2.7).
3. Mount the Conduit Bracket (supplied with the range in a
separate kit) inside the Opening For Electrical Connection
by screwing the 2 Fixing Screws (as indicated in figure 2.8).
4. Feed 3/4” (1.90 cm) trade size Conduit through the hole in the
Conduit Bracket and secure to the Conduit Bracket with a
Conduit Clamp (fig. 2.10).
5. Remove the 3 wire terminal nuts and washers from the
Terminal Block.
6. Remove the Ground Strap from the frame of range and
terminal by removing its screw and cutting it as shown in
figure-2.10.
7. Plug the terminal holes of conductors. The Neutral Wire of
the Power Cord must be connected to the neutral terminal
located in the center of Terminal Block; the Power Wires
must be connected to the outside terminals; the Ground Wire
must be attached to the frame of range by using the
(Ground) identified Grounding Screw.
8. Plug washers and tighten nuts securely.
9. Assemble the Terminal Block Access Plate.
Conduit
Neutral Wire
Power Wires
Terminal Block
Conduit
Bracket
Grounding Wire
Cut Ground Strap
Grounding Screw
Conduit Clamp
Fig. 2.10
Conduit
Neutral Wire
Power Wires
Terminal Block
Ground strap
Conduit
Bracket
Conduit Clamp
Fig. 2.9
3-Wire Conduit Installation
(See Figures 2.1, 2.7, 2.8 and 2.9)
1. Remove the Terminal Block Access Plate on the back of the
range by unscrewing the 4 fixing Screws (fig. 2.1).
2. Remove the Bracket and Strain Relief group by unscrewing
the Bracket Fixing Screws (2.7).
3. Mount the Conduit Bracket (supplied with the range in a
separate kit) inside the Opening For Electrical Connection
by screwing the 2 Fixing Screws (as indicated in Figure 2.8).
4. Feed 3/4” (1.90 cm) trade size Conduit through the hole in the
Conduit Bracket and secure to the Conduit Bracket with a
Conduit Clamp (fig. 2.9).
5. Remove the 3 wire terminal nuts and washers from the
Terminal Block.
6. Plug the terminal holes of conductors. The Neutral or
Ground Wire of the Power Cord must be connected to the
neutral terminal located in the center of Terminal Block. The
Power Wires must be connected to the outside terminals.
7. Plug washers and tighten nuts securely.
Do not remove Ground strap.
8. Assemble the Terminal Block Access Plate.
Strain Relief
Bracket
Bracket
Fixing Screws
Conduit
Bracket
Fixing Screws
Opening For
Electrical
Connection
Fig. 2.7
Fig. 2.8