Victory Refrigeration DRA-2D-S7-LD Refrigerator User Manual


 
Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.
Continuous product development may necessitate specification changes and design without notice.
Victory
Refrigeration,
Inc. Display
Refrigerators
(Sliding Full Length Doors)
CHARACTERISTICS TWO SECTION
Reach-In Pass-Thru
Width, Overall 52
1
/
8
52
1
/
8
Depth, Overall (incl. handles) 34
3
/
8
36
3
/
8
Height, Overall (incl. adj. legs) 84 84
Clear Sliding Door Width 19
1
/
2
19
1
/
2
Clear Full Door Height 50
1
/
8
50
1
/
8
Capacity Net (cubic feet) 46.5 48.0
No. of Half Doors 2 4
No. of Shelves 6 6
Shelf Area (square feet) 36.0 36.0
Cabinet Voltage 115/60/1 115/60/1
Feed Wires 2 3
Condensing Unit Voltage 115/60/1 208-230/60/1
Condensing Unit Size (HP)
1
/
2
3
/
4
Total Amperes 12.1 10.9
Crated dim. & wts.
Ht. Width Depth Cu.Ft. Lbs
Two Section 87 63
5
/
8
44
3
/
4
143.3 610
Approximate Pass-Thru weights, add 15%
FOR REMOTE MODELS– Substitute an “R” for the “S” in suffix. For
example: Model DRS-2D-
S7
-HD (self-contained) would be DRS-2D-
R7
-HD remote cabinet. Air circulating fans, expansion valve and plas-
ticized coil are provided. Condensing units not supplied. The following
units are recommended with
1
/
2
” O.D. Suction line,
1
/
4
” O.D. Liquid
line.
Dimensional tolerance ±
1
/
4
” Metric dimensions (MM)
REMOTE REFRIGERATION
Cond. Unit BTUH Cabinet Amps
Two Section
1
/
2
H.P. 4400 115/60/1 3.7
For Remote Pass-Thru–Consult factory
Copyright January 2004
Printed in U.S.A. 010420
PART OF AGA FOODSERVICE GROUP
14.12
(358)
34.38
(873)
32.38
(822)
PASS-THRU MODEL
REACH-IN MODEL
48.12
(1222)
34.38
(873)
36.38
(924)
84.00
(2133)
6.00
(152)
21.12
(536)
21.12
(536)
52.50
(1333)
52.12
(1323)
SURFACE MOUNTED
SLIDING GLASS DOORS
ELEC.
CONN.
ELEC.
CONN.
FRONT VIEW SIDE VIEW
NOTE: If cabinet is located directly against
wall and/or under low ceiling, a minimum
clearance of 2” is required.
We reserve the right to change
specifications and product design
without notice. Such revisions do not
entitle the buyer to corresponding
changes, improvements, additions or
replacements for previously purchased
equipment.