Viking BQC053T1 Oven User Manual


 
GAS
Burner rating
One bake burner, @ 20,000
BTU (5.7 kW) Nat./LP
Fixed piping installations
Check with local gas utility
company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
An installer-supplied gas shut-
off valve must be installed in
an easily accessible location.
All installer-supplied parts
must conform to local codes.
Must be isolated from the gas
supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that system
at test pressures equal to or
less than 1/2 psi (3.5 kPa).
Natural gas models
Water column pressure
o Operating pressure—4.0”
WCP
o Supply pressure of 6” – 14”
WCP
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the
7/8” (2.2 cm) male flare on
the regulator assembly.
LP/propane models
Water column pressure
o Operating pressure—10”
WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.
LP/propane tank installations
Water column pressure
o Operating pressure—10”
WCP
Includes high-capacity
hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector
o The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.
o The cylinder must be
provided with a shut-off
valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.
o The cylinder supply system
must be arranged for vapor
withdrawal and provided
with a listed OPD (overfilling
prevention device).
ELECTRICAL
• 9-volt DC battery for electronic
ignition
PLUMBING
Not applicable
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
OUTDOOR—COOKING
53”W. Outdoor Range
Ultra-Premium
Grill Cart with Gas Oven
UTILITY
REQUIREMENTS
Installation Requirements
BQC053T1
Outdoor Range
Ultra-Premium
Cart & Oven